two years of discharge and discomfort. Consulted several times and observation was recommended. A scleral buckle was seen intruded in the superior lid skin of left eye superiorly and in to the sclera inferiorly. Once it was pulled it was evident that a large piece of rigid silicon had made a deep tunnel in the skin.

IMG_0506~0.JPG
Silicon implant is seen inserted in to the superior lid skinvaatamisi: 449Patient with several months of discomfort, discharge, FB sensation after scleral buckle surgery.00000
(0 hinnangut)
IMG_0507.JPG
Silicon implant is seen inserted in to the superior lid skinvaatamisi: 461another view of the implant intruded in the lid skin00000
(0 hinnangut)
IMG_0508.JPG
Implant removed from the skin tunelvaatamisi: 512the extruded piece of silicon is seen after removal from the skin tunnel. It is still attached to the sclera, through a conjunctival hole00000
(0 hinnangut)
IMG_0509.JPG
Deep skin tunel remains after silicon buckle removedvaatamisi: 399superior lid skin tunnel made by 2 years of erosion of the buckle00000
(0 hinnangut)
IMAGE_A8F3620A-9E07-4F7A-92DE-1D2EA726A045.jpg
Buckle removedvaatamisi: 435Silicon implant had been extruded for 2 years00000
(0 hinnangut)
     
5 faili 1 lehel

two years of discharge and discomfort. Consulted several times and observation was recommended. A scleral buckle was seen intruded in the superior lid skin of left eye superiorly and in to the sclera inferiorly. Once it was pulled it was evident that a large piece of rigid silicon had made a deep tunnel in the skin.